Compare | Mfr Part # | Quantity Available | Series | Package | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Polarization | Mounting Type | Package / Case | Supplier Device Package | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
50 |
CSLA |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Open Loop |
550A |
1 |
Ratiometric, Voltage |
4.3mV/N |
- |
- |
- |
6V ~ 12V |
3µs |
20mA |
-25°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSLA |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
950A |
1 |
Ratiometric, Voltage |
2.3mV/N |
- |
- |
- |
6V ~ 12V |
3µs |
20mA |
-25°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSLA |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
125A |
1 |
Ratiometric, Voltage |
19.6mV/N |
- |
- |
- |
6V ~ 12V |
3µs |
20mA |
-25°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
1000A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 18V |
1µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
90A |
1 |
Ratiometric, Current |
- |
DC ~ 150kHz |
±0.2% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
90A |
1 |
Ratiometric, Current |
- |
DC ~ 150kHz |
±0.2% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
70A |
1 |
Ratiometric, Voltage |
- |
DC ~ 150kHz |
±1% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
100A |
1 |
Ratiometric, Current |
- |
DC ~ 150kHz |
±0.1% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
600A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 18V |
0.5µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
36A |
1 |
Ratiometric, Current |
- |
DC ~ 150kHz |
±0.2% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
36A |
1 |
Ratiometric, Current |
- |
DC ~ 150kHz |
±0.2% |
±0.5% |
±15V |
1µs |
10mA |
0°C ~ 70°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
200A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 15V |
0.5µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
200A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 15V |
0.5µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Obsolete |
AC/DC |
Hall Effect, Closed Loop |
200A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 15V |
0.5µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
CSN |
Bulk |
Active |
AC/DC |
Hall Effect, Closed Loop |
200A |
1 |
Ratiometric, Current |
- |
- |
- |
±0.5% |
±12V ~ 15V |
0.5µs |
14mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
Copyright © 2024. QUATTRO TECHNOLOGY CO.,LTD All rights reserved.