Compare Mfr Part # Quantity Available Series Package Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Polarization Mounting Type Package / Case Supplier Device Package

F01P050S05 SENSOR CURRENT FLUX GATE 50A AC

50

F01P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

50A

1

Ratiometric, Voltage

12.5mV/A

300kHz

±1%

±1.7%

5V

0.3µs

55mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F02P006S05 SENSOR CURRENT FLUX GATE 6A AC

50

F02P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

6A

1

Ratiometric, Voltage

104.2mV/A

300kHz

±1%

±1.7%

5V

0.3µs

25mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F02P015S05 SENSOR CURRENT FLUX GATE 15A AC

50

F02P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

15A

1

Ratiometric, Voltage

41.67mV/A

300kHz

±1%

±1.2%

5V

0.3µs

30mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F02P025S05 SENSOR CURRENT FLUX GATE 25A AC

50

F02P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

25A

1

Ratiometric, Voltage

25mV/A

300kHz

±1%

±1%

5V

0.3µs

35mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F02P050S05 SENSOR CURRENT FLUX GATE 50A AC

50

F02P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

50A

1

Ratiometric, Voltage

12.5mV/A

300kHz

±1%

±0.9%

5V

0.3µs

55mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F03P006S05 SENSOR CURRENT FLUX GATE 6A AC

50

F03P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

6A

1

Ratiometric, Voltage

104.2mV/A

300kHz

±1%

±1.7%

5V

0.3µs

25mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

F03P015S05 SENSOR CURRENT FLUX GATE 15A AC

50

F03P

Bulk

Obsolete

AC

Flux Gate, Closed Loop

15A

1

Ratiometric, Voltage

41.7mV/A

300kHz

±1%

±1.2%

5V

0.3µs

30mA

-40°C ~ 105°C

Bidirectional

Through Hole

Module

-

L06P300S05 SENSOR CURRENT HALL 300A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

300A

1

Ratiometric, Voltage

-

DC ~ 100kHz

±1%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L06P500S05 SENSOR CURRENT HALL 500A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

500A

1

Ratiometric, Voltage

-

DC ~ 100kHz

±1%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L06P600S05 SENSOR CURRENT HALL 600A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

600A

1

Ratiometric, Voltage

-

DC ~ 100kHz

±1%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L06P700S05 SENSOR CURRENT HALL 700A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

700A

1

Ratiometric, Voltage

-

DC ~ 100kHz

±1%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L07P003S05 SENSOR CURRENT HALL 3A AC/DC

50

L07P

Bulk

Active

AC/DC

Hall Effect, Open Loop

3A

1

Ratiometric, Voltage

-

DC ~ 100kHz

±1%

-

5V

5µs

30mA

-30°C ~ 80°C

Bidirectional

Through Hole

Module

-

L32P050S05BFS SENSOR CURRENT HALL 50A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

50A

1

Ratiometric, Voltage

-

DC ~ 50kHz

±0.5%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L32P050S05FS SENSOR CURRENT HALL 50A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

50A

1

Ratiometric, Voltage

-

DC ~ 50kHz

±0.5%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

L32P100S05BFS SENSOR CURRENT HALL 100A AC/DC

50

-

Bulk

Active

AC/DC

Hall Effect, Open Loop

100A

1

Ratiometric, Voltage

-

DC ~ 50kHz

±0.5%

-

5V

5µs

15mA

-40°C ~ 85°C

Bidirectional

Through Hole

Module, Single Pass Through

-

  • F01P050S05

    SENSOR CURRENT FLUX GATE 50A AC

    Details
  • F02P006S05

    SENSOR CURRENT FLUX GATE 6A AC

    Details
  • F02P015S05

    SENSOR CURRENT FLUX GATE 15A AC

    Details
  • F02P025S05

    SENSOR CURRENT FLUX GATE 25A AC

    Details
  • F02P050S05

    SENSOR CURRENT FLUX GATE 50A AC

    Details
  • F03P006S05

    SENSOR CURRENT FLUX GATE 6A AC

    Details
  • F03P015S05

    SENSOR CURRENT FLUX GATE 15A AC

    Details
  • L06P300S05

    SENSOR CURRENT HALL 300A AC/DC

    Details
  • L06P500S05

    SENSOR CURRENT HALL 500A AC/DC

    Details
  • L06P600S05

    SENSOR CURRENT HALL 600A AC/DC

    Details
  • L06P700S05

    SENSOR CURRENT HALL 700A AC/DC

    Details
  • L07P003S05

    SENSOR CURRENT HALL 3A AC/DC

    Details
  • L32P050S05BFS

    SENSOR CURRENT HALL 50A AC/DC

    Details
  • L32P050S05FS

    SENSOR CURRENT HALL 50A AC/DC

    Details
  • L32P100S05BFS

    SENSOR CURRENT HALL 100A AC/DC

    Details

Copyright © 2024. QUATTRO TECHNOLOGY CO.,LTD All rights reserved.