Compare | Mfr Part # | Quantity Available | Series | Package | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Polarization | Mounting Type | Package / Case | Supplier Device Package | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||||||
50 |
F01P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
50A |
1 |
Ratiometric, Voltage |
12.5mV/A |
300kHz |
±1% |
±1.7% |
5V |
0.3µs |
55mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F02P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
6A |
1 |
Ratiometric, Voltage |
104.2mV/A |
300kHz |
±1% |
±1.7% |
5V |
0.3µs |
25mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F02P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
15A |
1 |
Ratiometric, Voltage |
41.67mV/A |
300kHz |
±1% |
±1.2% |
5V |
0.3µs |
30mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F02P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
25A |
1 |
Ratiometric, Voltage |
25mV/A |
300kHz |
±1% |
±1% |
5V |
0.3µs |
35mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F02P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
50A |
1 |
Ratiometric, Voltage |
12.5mV/A |
300kHz |
±1% |
±0.9% |
5V |
0.3µs |
55mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F03P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
6A |
1 |
Ratiometric, Voltage |
104.2mV/A |
300kHz |
±1% |
±1.7% |
5V |
0.3µs |
25mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
F03P |
Bulk |
Obsolete |
AC |
Flux Gate, Closed Loop |
15A |
1 |
Ratiometric, Voltage |
41.7mV/A |
300kHz |
±1% |
±1.2% |
5V |
0.3µs |
30mA |
-40°C ~ 105°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
300A |
1 |
Ratiometric, Voltage |
- |
DC ~ 100kHz |
±1% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
500A |
1 |
Ratiometric, Voltage |
- |
DC ~ 100kHz |
±1% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
600A |
1 |
Ratiometric, Voltage |
- |
DC ~ 100kHz |
±1% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
700A |
1 |
Ratiometric, Voltage |
- |
DC ~ 100kHz |
±1% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
L07P |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
3A |
1 |
Ratiometric, Voltage |
- |
DC ~ 100kHz |
±1% |
- |
5V |
5µs |
30mA |
-30°C ~ 80°C |
Bidirectional |
Through Hole |
Module |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
50A |
1 |
Ratiometric, Voltage |
- |
DC ~ 50kHz |
±0.5% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
50A |
1 |
Ratiometric, Voltage |
- |
DC ~ 50kHz |
±0.5% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
|||||||||||||||||||||||||
50 |
- |
Bulk |
Active |
AC/DC |
Hall Effect, Open Loop |
100A |
1 |
Ratiometric, Voltage |
- |
DC ~ 50kHz |
±0.5% |
- |
5V |
5µs |
15mA |
-40°C ~ 85°C |
Bidirectional |
Through Hole |
Module, Single Pass Through |
- |
Copyright © 2024. QUATTRO TECHNOLOGY CO.,LTD All rights reserved.